Product Information

JP-S Series

  • Basic Information
  • Product Lineup
  • Main Specifications
  JP-S0501 JP-S1001 JP-S1501 JP-S2001 JP-S3001 JP-S5R01 JP-S10R1 JP-S20T1
Approach Speed
(mm/sec)
216 200 210 200 100 50
Repeatability
(mm)*1
±0.01
Main Unit Dimensions
WxD
x
H(mm)
65x155
x
455  
~805
65x155
x
455  
~655
80x196
x
505  
~995
80x196
x
505  
~925
100x259
x
570  
~930
148x365
x
643  
~943
200x465
x
889   
~1,189
292x442
x
1,499   
~1,699
Weight(kg) 12~18 12~16 20~35 20~33 35~55 98~135 198~272 387~437
Controller Dimensions
WxDxH(mm)
79×163×287 104×188×328 147x188x365
Weight(kg) 3 5 8

*1 Position repeatability is not a guarantee of absolute precision.

* These values are for standard models and may differ with specification modifications.

Please contact us for details.

  • When configuring your facility for use with this product, be sure to perform your own risk assessment.

Common Specifications

Pressing Modes
Constant Speed Pressing Position Stop
Distance Stop
Load Stop
Increased Load Stop
Event Stop
Constant Load Pressing Time Stop
Position Stop
Distance Stop
Event Stop
Sensor Modes Step Sensors

Position Sensor (Start of Step)

Position Sensor (End of Step)

Load Sensor Given Position 
Given Distance
Peak Load Sensor Given Position
Given Distance
Bottom Load Sensor Given Position
Given Distance
Top Load Sensor Given Position
Given Distance
Valley Load Sensor Given Position
Given Distance
Peak to Peak Load Sensor Given Position
Given Distance
Differential 1 Sensor Given Position
Given Distance
Differential 2 Sensor Given Position
Given Distance
Load Path Sensor Given Position
Given Distance
Load Zone Sensors
Load Sensor Zone 1
Zone 2
Zone 3
Zone 32
Sensor judgment made for the whole program
Set up to 32 (position range) zones
Program Sensors
Register Difference Sensor
Register Sum Sensor
Register Value Sensor
Sensor judgment made when all steps are complete
External Interface Ethernet, RS-232C
Open Fieldbus*2 DeviceNet, CC-Link, PROFIBUS, CANopen, PROFINET, EtherNet/IP : Please choose when you place your order.
External Input/Output DIO (I/O: 17 inputs 16 outputs, NPN/PNP: Please choose when you place your order.)
Other Outputs Motor Encoder Output, Analog Monitor Output, Load Cell Output
Setting Device PC or Optional Pendant Unit
Drive Power Source Single Phase, 3 Phase 180~250V (for presses up to 20kN)
3 Phase 180~250V (for presses 30kN and larger)
Controller Power Source DC24V
Temperature 0~40°C
Relative Humidity 20~90% (Without condensation)
Ingress Protection (IP) Rating IP20

*2 CANopen is compatible with JP-S System Software Ver.4.8.0 and above. PROFINET is compatible with JP-S System Software Ver.6.2.1 and above. EtherNet/IP is compatible with JP-S System Software Ver.6.3.1 and above.

  • Specifications may be modified without prior notice to improve product quality.

Standard Accessories

  • Main Unit Cable
  • Power Cable
  • Operation Manual (CD-ROM)

For more details, please refer to the product catalog.

Optional Attachments

  • PC Software: JP-S SaS System Windows® 7/ Windows® 8 compatible)*3
  • Pendant Unit
  • DIN rail attachment board

*3 In order to operate the JP-S SaS System with a touch panel PC (HMI), make sure to use the Microsoft Windows® Embedded Standard 7 “WS7P” Windows Touch package license.

For more details, please refer to the product catalog.